OPERATIONALISATION

Measurement of Grip strength 

Instrument used: Jamar Hand held dynamometer



Arm position

  • In sitting
  • Shoulder adducted and neutrally rotated
  • Elbow 90 degrees flexion
  • Forearm and wrist in neutral position










Placement of dynamometer
·         The handle of the dynamometer will be adjusted properly.
·         The base of the dynamometer should rest on first metacarpal and the handle should rest on middle of four fingers






Dynamometer Calibration: 
This instrument is calibrated at the factory by loading it at the center with weight and making appropriate adjustments in the gauge. (From Jamar instruction manual)




Before each measurement:
Rotate the needle counter-clockwise to 0 after each measurement



Recording of measurement:
The peak hold needle will automatically record the highest force the person has exerted



Measurement of forearm circumference


Instrument used: Butterfly brand measuring tape





Placement of measuring tape: 
2 fingers spacing away from the elbow crease, based on each individual. Ensure that the tape is not too tight or too loose and is lying flat on the skin.